| More |
LINE ITEM NUMBER
|
COMMODITY TYPE
|
STATE TERM CONTRACT ID
|
AGENCY SOLICITATION NUMBER
|
Quantity |
Unit Price |
Total Unit Price |
|
|
1
|
Two way radios
|
|
|
1.0000
|
$60,837.0000
|
$60,837.00
|
| INTERNATIONAL TOWER, LLLC (ITL) TO PROVIDE TURNKEY INSTALLATION SERVICE FOR A 50-FOOT ABOVE-GROUND-LEVEL (AGL) SELF-SUPPORTING COMMUNICATION TOWER AT THE FLORIDA DEPARTMENT OF CORRECTIONS FACILITY LOC... |
| Line Item Description: INTERNATIONAL TOWER, LLLC (ITL) TO PROVIDE TURNKEY INSTALLATION SERVICE FOR A 50-FOOT ABOVE-GROUND-LEVEL (AGL) SELF-SUPPORTING COMMUNICATION TOWER AT THE FLORIDA DEPARTMENT OF CORRECTIONS FACILITY LOCATED AT THE MADISON CORRECTIONAL FACILITY. THE TOWER SHALL BE DESIGNED IN ACCORDANCE WITH ANSI/TI-222-I. CATEGORY III, WITH A DESIGN WIND SPEED OF 138 MPH PER ASCE 7-22. A CUSTOM FACE MOUNT PROVIDING A 3-FOOT STANDOFF DISTANCE SHALL ALSO BE INCLUDED WORK UNDER THIS SCOPE OF WORK INCLUDES DECOMMISSION AND REMOVAL OF THE EXISTING TOWER SITE WORK. THE NEW TOWER FOUNDATION INSTALLATION, TOWER ERECTION, GROUNDING SYSTEM INSTALLATION, ICE BRIDGE INSTALLATION, ASSOCIATED SITE WORK, |
| Method of Procurement: Emergency procurement [s. 287.057(3)(a), F.S.] & [Rule 60A-1.045, F.A.C.] |
Line Split Details:
| Split Accounting Line Number: 1 |
| FLAIR Contract ID: |
| Org. Code and Description: 70024100102 - |
| Object Code and Description: 242047 - |
| Account Code: 70-10-1-000364-70031100-00-100777-00 |
| Split Amount: $60,837.00 |
|
|
|
2
|
Two way radios
|
|
|
1.0000
|
$30,036.0000
|
$30,036.00
|
| ITL SHALL PROVIDE AND ONE (1) 50-FOOT ROHM RT, OR EQUIVALENT, LIGHT DUTY SELF-SUPPORTING STRUCTURE. THE PROPOSED TOWER SHALL INCLUDE STEP BOLTS AND A SAFETY CLIMB SYSTEM. THE TOWER TO BE CONSTRUCTED ... |
| Line Item Description: ITL SHALL PROVIDE AND ONE (1) 50-FOOT ROHM RT, OR EQUIVALENT, LIGHT DUTY SELF-SUPPORTING STRUCTURE. THE PROPOSED TOWER SHALL INCLUDE STEP BOLTS AND A SAFETY CLIMB SYSTEM. THE TOWER TO BE CONSTRUCTED OF HOT-DIPPED GALVANIZED STEEL AND SHALL BE DELIVERED DIRECTLY FROM THE MANUFACTURER. ITL SHALL TREAT ANY EXPOSED AREAS OF STEEL RESULTING FROM CONSTRUCTION ACTIVITIES OR GRUNDING WORK WITH COLD GALVANIZATION PRIOR TO THE PROJECT BEING CLOSED. PLEASE NOTE THAT THE TOWER IS A FIXED-HEIGHT STRUCTURE DESIGNED TO REMAIN STATIONARY AND DOES NOT ALLOW FOR REGULAR RAISING OR LOWERING. THE TOWER DESIGNED SHALL BE APPROVED BY THE CUSTOMER PRIOR TO THE ORDER BEING PLACED. ANY CHANGES TO THE TOWER DESIGN AFTER APPROVAL MAY RESULT IN INCREASED PRICING NOT INCLUDED BELOW. THE TOWER CANNOT BE RETURNED OR CANCELLED ONCE THE PLANT FABRICATION HAS BEGUN. |
| Method of Procurement: Emergency procurement [s. 287.057(3)(a), F.S.] & [Rule 60A-1.045, F.A.C.] |
Line Split Details:
| Split Accounting Line Number: 1 |
| FLAIR Contract ID: |
| Org. Code and Description: 70024100102 - |
| Object Code and Description: 242047 - |
| Account Code: 70-10-1-000364-70031100-00-100777-00 |
| Split Amount: $30,036.00 |
|
|
|
3
|
Two way radios
|
|
|
1.0000
|
$4,980.0000
|
$4,980.00
|
| ITL SHALL SUPPLY 2 ANTENNA (MODEL ANT734-960F2/809-896 MHZ) WITH 2.5DB GAIN AND 7/8 LINE FOR EACH ANTENNA |
| Line Item Description: ITL SHALL SUPPLY 2 ANTENNA (MODEL ANT734-960F2/809-896 MHZ) WITH 2.5DB GAIN AND 7/8 LINE FOR EACH ANTENNA |
| Method of Procurement: Emergency procurement [s. 287.057(3)(a), F.S.] & [Rule 60A-1.045, F.A.C.] |
Line Split Details:
| Split Accounting Line Number: 1 |
| FLAIR Contract ID: |
| Org. Code and Description: 70024100102 - |
| Object Code and Description: 242047 - |
| Account Code: 70-10-1-000364-70031100-00-100777-00 |
| Split Amount: $4,980.00 |
|